Name:
  • M30 Melt pressure transmitters
Features:
  • • Pressure ranges from: 0-35 to 0-2000 bar / 0-500 to 0-30000 psi
  • • Accuracy: <±0.25% FSO (H); <±0.5% FSO (M)
  • • Fluid-filled system for temperature stability
  • • Mercury filling volume: M30 (30mm3), M31-M32-M33 (40mm3)
  • • 1/2-20UNF, M18x1.5 standard threads; other types available on request
  • • Standard diaphragm is 15-5 PH stainless steel with GTP coating
  • • 17-7 PH corrugated diaphragm with GTP coating for ranges below 100bar-1500psi
Specifications:
  • Accuracy up to ±0.25%FSO
  • Resolution: Infinite
  • Measurement range = 0..35 to 0..2000bar / 0..500 to 0..30000psi
  • Maximum overpressure = 2 x FS (1.5 x FS above1000bar)
  • Supply voltage = 6..12Vdc (10Vdc typical)
  • Strain gage bridge resistance = 350 Ohm (550 below 100bar) Isolation resistance (at 50Vdc) = >1000 MOhm
  • Zero balance = ±0.5% FSO
  • Calibration signal = 80% FSO
  • Compensated temperature range = 0...+100°C / 32...212°F
  • Maximum temperature range = -30...+120°C / -22...250°F
  • Thermal drift in compensated range < 0.02% FSO/°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature = 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Protection degree (with 6-pin mating connector): IP65

Name:
  • M31 Melt pressure transmitters
Features:
  • • Pressure ranges from: 0-35 to 0-2000 bar / 0-500 to 0-30000 psi
  • • Accuracy: <±0.25% FSO (H); <±0.5% FSO (M)
  • • Fluid-filled system for temperature stability
  • • Mercury filling volume: M30 (30mm3), M31-M32-M33 (40mm3)
  • • 1/2-20UNF, M18x1.5 standard threads; other types available on request
  • • Standard diaphragm is 15-5 PH stainless steel with GTP coating
  • • 17-7 PH corrugated diaphragm with GTP coating for ranges below 100bar-1500psi
Specifications:
  • Accuracy up to ±0.25%FSO
  • Resolution: Infinite
  • Measurement range = 0..35 to 0..2000bar / 0..500 to 0..30000psi
  • Maximum overpressure = 2 x FS (1.5 x FS above1000bar)
  • Supply voltage = 6..12Vdc (10Vdc typical)
  • Strain gage bridge resistance = 350 Ohm (550 below 100bar) Isolation resistance (at 50Vdc) = >1000 MOhm
  • Zero balance = ±0.5% FSO
  • Calibration signal = 80% FSO
  • Compensated temperature range = 0...+100°C / 32...212°F
  • Maximum temperature range = -30...+120°C / -22...250°F
  • Thermal drift in compensated range < 0.02% FSO/°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature = 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Protection degree (with 6-pin mating connector): IP65

Name:
  • M32 Melt pressure transmitters
Features:
  • • Pressure ranges from: 0-35 to 0-2000 bar / 0-500 to 0-30000 psi
  • • Accuracy: <±0.25% FSO (H); <±0.5% FSO (M)
  • • Fluid-filled system for temperature stability
  • • Mercury filling volume: M30 (30mm3), M31-M32-M33 (40mm3)
  • • 1/2-20UNF, M18x1.5 standard threads; other types available on request
  • • Standard diaphragm is 15-5 PH stainless steel with GTP coating
  • • 17-7 PH corrugated diaphragm with GTP coating for ranges below 100bar-1500psi
Specifications:
  • Accuracy up to ±0.25%FSO
  • Resolution: Infinite
  • Measurement range = 0..35 to 0..2000bar / 0..500 to 0..30000psi
  • Maximum overpressure = 2 x FS (1.5 x FS above1000bar)
  • Supply voltage = 6..12Vdc (10Vdc typical)
  • Strain gage bridge resistance = 350 Ohm (550 below 100bar) Isolation resistance (at 50Vdc) = >1000 MOhm
  • Zero balance = ±0.5% FSO
  • Calibration signal = 80% FSO
  • Compensated temperature range = 0...+100°C / 32...212°F
  • Maximum temperature range = -30...+120°C / -22...250°F
  • Thermal drift in compensated range < 0.02% FSO/°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature = 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Protection degree (with 6-pin mating connector): IP65

Name:
  • ME0 Melt pressure transmitters
Features:
  • • Pressure ranges from: 0-35 to 0-2000 bar / 0-500 to 0-30000 psi
  • • Accuracy: <±0.25% FSO (H); <±0.5% FSO (M)
  • • Fluid-filled system for temperature stability
  • • Mercury filling volume: M30 (30mm3), M31-M32-M33 (40mm3)
  • • 1/2-20UNF, M18x1.5 standard threads; other types available on request
  • • Standard diaphragm is 15-5 PH stainless steel with GTP coating
  • • 17-7 PH corrugated diaphragm with GTP coating for ranges below 100bar-1500psi
Specifications:
  • Accuracy up to ±0.25%FSO
  • Resolution: Infinite
  • Measurement range = 0..35 to 0..2000bar / 0..500 to 0..30000psi
  • Maximum overpressure = 2 x FS (1.5 x FS above1000bar)
  • Supply voltage = 10..30Vdc
  • Maximum current absorption = 32mA
  • Output signal full scale = 20 mA
  • Isolation resistance (at 50Vdc) = >1000 MOhm
  • Zero balance = 4mA Calibration signal = 80% FSO
  • Compensated temperature range = 0...+85°C
  • Operating temperature range = -30...+105°C
  • Thermal drift in compensated range < 0.02% FSO/°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature = 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Protection degree (with 6-pin mating connector): IP65

Name:
  • ME1 Melt pressure transmitters
Features:
  • • Pressure ranges from: 0-35 to 0-2000 bar / 0-500 to 0-30000 psi
  • • Accuracy: <±0.25% FSO (H); <±0.5% FSO (M)
  • • Fluid-filled system for temperature stability
  • • Mercury filling volume: M30 (30mm3), M31-M32-M33 (40mm3)
  • • 1/2-20UNF, M18x1.5 standard threads; other types available on request
  • • Standard diaphragm is 15-5 PH stainless steel with GTP coating
  • • 17-7 PH corrugated diaphragm with GTP coating for ranges below 100bar-1500psi
Specifications:
  • Accuracy up to ±0.25%FSO
  • Resolution: Infinite
  • Measurement range = 0..35 to 0..2000bar / 0..500 to 0..30000psi
  • Maximum overpressure = 2 x FS (1.5 x FS above1000bar)
  • Supply voltage = 10..30Vdc
  • Maximum current absorption = 32mA
  • Output signal full scale = 20 mA
  • Isolation resistance (at 50Vdc) = >1000 MOhm
  • Zero balance = 4mA Calibration signal = 80% FSO
  • Compensated temperature range = 0...+85°C
  • Operating temperature range = -30...+105°C
  • Thermal drift in compensated range < 0.02% FSO/°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature = 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Protection degree (with 6-pin mating connector): IP65

Name:
  • ME2 Melt pressure transmitters
Features:
  • • Pressure ranges from: 0-35 to 0-2000 bar / 0-500 to 0-30000 psi
  • • Accuracy: <±0.25% FSO (H); <±0.5% FSO (M)
  • • Fluid-filled system for temperature stability
  • • Mercury filling volume: M30 (30mm3), M31-M32-M33 (40mm3)
  • • 1/2-20UNF, M18x1.5 standard threads; other types available on request
  • • Standard diaphragm is 15-5 PH stainless steel with GTP coating
  • • 17-7 PH corrugated diaphragm with GTP coating for ranges below 100bar-1500psi
Specifications:
  • Accuracy up to ±0.25%FSO
  • Resolution: Infinite
  • Measurement range = 0..35 to 0..2000bar / 0..500 to 0..30000psi
  • Maximum overpressure = 2 x FS (1.5 x FS above1000bar)
  • Supply voltage = 10..30Vdc
  • Maximum current absorption = 32mA
  • Output signal full scale = 20 mA
  • Isolation resistance (at 50Vdc) = >1000 MOhm
  • Zero balance = 4mA Calibration signal = 80% FSO
  • Compensated temperature range = 0...+85°C
  • Operating temperature range = -30...+105°C
  • Thermal drift in compensated range < 0.02% FSO/°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature = 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Protection degree (with 6-pin mating connector): IP65

Name:
  • MN0 Melt pressure transmitters
Features:
  • • Pressure ranges from: 0-35 to 0-2000 bar / 0-500 to 0-30000 psi
  • • Accuracy: <±0.25% FSO (H); <±0.5% FSO (M)
  • • Fluid-filled system for temperature stability
  • • Mercury filling volume: M30 (30mm3), M31-M32-M33 (40mm3)
  • • Drift auto compensation function (SP version)
  • • 1/2-20UNF, M18x1.5 standard threads; other types available on request
  • • Standard diaphragm is 15-5 PH stainless steel with GTP coating
  • • 17-7 PH corrugated diaphragm with GTP coating for ranges below 100bar
Specifications:
  • Accuracy up to ±0.25%FSO
  • Resolution: Infinite
  • Measurement range = 0..35 to 0..2000bar / 0..500 to 0..30000psi
  • Maximum overpressure = 2 x FS (1.5 x FS above1000bar)
  • Supply voltage = 10..30Vdc
  • Maximum current absorption = 25mA
  • Isolation resistance (at 50Vdc) = >1000 MOhm
  • Zero balance = 0~0.1Vdc
  • Volt. Spike protection > 2KV Response time (0~90% FSO) < 1msec
  • Calibration signal = 80% FSO
  • Compensated temperature range = 0...+85°C
  • Operating temperature range = -30...+105°C
  • Thermal drift in compensated range < 0.02% FSO/°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature < 0.003 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Protection degree (with 6-pin mating connector): IP65

Name:
  • MN2 Melt pressure transmitters
Features:
  • • Pressure ranges from: 0-35 to 0-2000 bar / 0-500 to 0-30000 psi
  • • Accuracy: <±0.25% FSO (H); <±0.5% FSO (M)
  • • Fluid-filled system for temperature stability
  • • Mercury filling volume: M30 (30mm3), M31-M32-M33 (40mm3)
  • • Drift auto compensation function (SP version)
  • • 1/2-20UNF, M18x1.5 standard threads; other types available on request
  • • Standard diaphragm is 15-5 PH stainless steel with GTP coating
  • • 17-7 PH corrugated diaphragm with GTP coating for ranges below 100bar
Specifications:
  • Accuracy up to ±0.25%FSO
  • Resolution: Infinite
  • Measurement range = 0..35 to 0..2000bar / 0..500 to 0..30000psi
  • Maximum overpressure = 2 x FS (1.5 x FS above1000bar)
  • Supply voltage = 10..30Vdc
  • Maximum current absorption = 25mA
  • Isolation resistance (at 50Vdc) = >1000 MOhm
  • Zero balance = 0~0.1Vdc
  • Volt. Spike protection > 2KV Response time (0~90% FSO) < 1msec
  • Calibration signal = 80% FSO
  • Compensated temperature range = 0...+85°C
  • Operating temperature range = -30...+105°C
  • Thermal drift in compensated range < 0.02% FSO/°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature < 0.003 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Protection degree (with 6-pin mating connector): IP65

Name:
  • M51 Mechanical melt pressure gauge
Features:
  • • Economically priced
  • • 1.5 times overload capacity
  • • Easy-to-read display
  • • 1/2-20 UNF thread standard, M18 x 1.5 also available
  • • 15-5 PH stainless steel diaphragm with Armoloy coating standard
  • • No power required
Specifications:
  • Accuracy up to ±0.1%FSO
  • Measurement range = 0..350 to 0..700bar / 0..5000 to 0..10000psi
  • Maximum overpressure = 1.5 x FS
  • Housing temperature range = -30...+85°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature < 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Housing temperature range = -30...+85°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature < 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”

Name:
  • M50 Mechanical melt pressure gauge
Features:
  • • Economically priced
  • • 1.5 times overload capacity
  • • Easy-to-read display
  • • 1/2-20 UNF thread standard, M18 x 1.5 also available
  • • 15-5 PH stainless steel diaphragm with Armoloy coating standard
  • • No power required
Specifications:
  • Accuracy up to ±0.1%FSO
  • Measurement range = 0..350 to 0..700bar / 0..5000 to 0..10000psi
  • Maximum overpressure = 1.5 x FS
  • Housing temperature range = -30...+85°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature < 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Housing temperature range = -30...+85°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature < 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”

Name:
  • M52 Mechanical melt pressure gauge
Features:
  • • Economically priced
  • • 1.5 times overload capacity
  • • Easy-to-read display
  • • 1/2-20 UNF thread standard, M18 x 1.5 also available
  • • 15-5 PH stainless steel diaphragm with Armoloy coating standard
  • • No power required
Specifications:
  • Accuracy up to ±0.1%FSO
  • Measurement range = 0..350 to 0..700bar / 0..5000 to 0..10000psi
  • Maximum overpressure = 1.5 x FS
  • Housing temperature range = -30...+85°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature < 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Housing temperature range = -30...+85°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature < 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”

 Name:
  • M60 Digital melt pressure gauge
Features:
  • • Better than ±0.50% accuracy
  • • Economically priced
  • • 2 times overload capacity
  • • 1/2-20 UNF thread standard, M18x1.5 also available
  • • One alarm standard
  • • 4-20 mA retransmission standard
  • • 15-5 stainless steel diaphragm with Armoloy coating standard
  • • 17-7 PH corrugated diaphragm with TiN coating
Specifications:
  • Accuracy up to ±0.50%FSO
  • Measurement range = 0..350 to 0..1000bar / 0..5000 to 0..15000psi
  • Maximum overpressure = 2 x FS
  • Supply voltage = 115 or 230 Vac
  • Retransmission of Pressure Value = 4-20mA
  • Maximum housing temperature < 55°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature < 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Alarm: C relay 5A

 Name:
  • M61 Digital melt pressure gauge
Features:
  • • Better than ±0.50% accuracy
  • • Economically priced
  • • 2 times overload capacity
  • • 1/2-20 UNF thread standard, M18x1.5 also available
  • • One alarm standard
  • • 4-20 mA retransmission standard
  • • 15-5 stainless steel diaphragm with Armoloy coating standard
  • • 17-7 PH corrugated diaphragm with TiN coating
Specifications:
  • Accuracy up to ±0.50%FSO
  • Measurement range = 0..350 to 0..1000bar / 0..5000 to 0..15000psi
  • Maximum overpressure = 2 x FS
  • Supply voltage = 115 or 230 Vac
  • Retransmission of Pressure Value = 4-20mA
  • Maximum housing temperature < 55°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature < 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Alarm: C relay 5A

 Name:
  • M62 Digital melt pressure gauge
Features:
  • • Better than ±0.50% accuracy
  • • Economically priced
  • • 2 times overload capacity
  • • 1/2-20 UNF thread standard, M18x1.5 also available
  • • One alarm standard
  • • 4-20 mA retransmission standard
  • • 15-5 stainless steel diaphragm with Armoloy coating standard
  • • 17-7 PH corrugated diaphragm with TiN coating
Specifications:
  • Accuracy up to ±0.50%FSO
  • Measurement range = 0..350 to 0..1000bar / 0..5000 to 0..15000psi
  • Maximum overpressure = 2 x FS
  • Supply voltage = 115 or 230 Vac
  • Retransmission of Pressure Value = 4-20mA
  • Maximum housing temperature < 55°C
  • Diaphragm maximum temperature < 400°C / 750°F
  • Zero drift due to change in process temperature < 0.02 bar/°C
  • Thermocouple (model M32) STD : type “J”
  • Alarm: C relay 5A


MOBILE:13301708887 Copyright: TheTrademark of ARICO Technology Co.Ltd