PRODUCTS | GEFRAN Melt Pressure Transducers >> GEFRAN Melt Pressure Transducers >> Content |
- M32 Melt pressure transmitters
- • Pressure ranges from: 0-35 to 0-2000 bar / 0-500 to 0-30000 psi
- • Accuracy: <±0.25% FSO (H); <±0.5% FSO (M)
- • Fluid-filled system for temperature stability
- • Mercury filling volume: M30 (30mm3), M31-M32-M33 (40mm3)
- • 1/2-20UNF, M18x1.5 standard threads; other types available on request
- • Standard diaphragm is 15-5 PH stainless steel with GTP coating
- • 17-7 PH corrugated diaphragm with GTP coating for ranges below 100bar-1500psi
- Accuracy up to ±0.25%FSO
- Resolution: Infinite
- Measurement range = 0..35 to 0..2000bar / 0..500 to 0..30000psi
- Maximum overpressure = 2 x FS (1.5 x FS above1000bar)
- Supply voltage = 6..12Vdc (10Vdc typical)
- Strain gage bridge resistance = 350 Ohm (550 below 100bar) Isolation resistance (at 50Vdc) = >1000 MOhm
- Zero balance = ±0.5% FSO
- Calibration signal = 80% FSO
- Compensated temperature range = 0...+100°C / 32...212°F
- Maximum temperature range = -30...+120°C / -22...250°F
- Thermal drift in compensated range < 0.02% FSO/°C
- Diaphragm maximum temperature < 400°C / 750°F
- Zero drift due to change in process temperature = 0.02 bar/°C
- Thermocouple (model M32) STD : type “J”
- Protection degree (with 6-pin mating connector): IP65